Continuous Rating Quick Selection Chart - kW

                        
       

Engine

Model

Build

List

Gross Continuous Rating - kW

1500

1600

1700

1800

1900

2000

2100

2200

2300

2400

2500

2600

2700

2800

2900

3000

400 SERIES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

403C-11

IOPU

  8.0

  8.8

  9.2

10.0

10.6

11.2

11.8

12.3

12.8

13.2

13.6

14.2

14.5

15.0

15.3

15.6

403C-15

HL81385U

10.8

12.8

13.6

14.4

15.2

16.0

16.6

17.4

17.8

18.4

18.8

19.2

19.5

19.8

20.0

20.2

404C-22

HP81387U

17.6

18.8

20.0

20.8

22.4

24.0

24.8

26.0

26.8

27.6

28.4

28.8

29.6

30.0

30.0

30.4

404C-22T

HRC28120

25.5

27.0

29.0

30.9

31.5

33.0

34.0

35.7

36.5

37.4

37.7

37.8

37.8

38.0

3.1524 SERIES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.1524

CM50503

26

28

29

30

31

32

32

33

34

35

4.41 SERIES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.41

LM50890

40

43

45

47

49

50

51

53

53

54

1100 SERIES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1104A-44

RR51292

41

43

45

48

50

51

53

55

57

58

1104A-44T

RS51293

57

60

63

65

67

68

70

71

71

72

1000 SERIES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1006-6

YA51063

60

64

67

71

74

77

79

82

83

84

84

85

1006-6T

YB51071

74

79

83

88

91

95

98

101

102

103

104

105

1006-6TW

YD51082

83

88

94

99

103

107

110

114

115

117

118

119

1300 SERIES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1306-E87T

 

130

137

141

146

148

150

152

153

1306-E87TA

 

215

220

222

225

225

225

224

223

COMMENTS

§         Gross rating based on BSAU 141a: 1971 – does not include cooling fan, charge alternator etc.    

§         Parasitic loads for radiator cooling:

                                    400 Series: Fan and Alternator combined – 2kW

                                    1000 & 1100 Series: Fan and alternator combined – 3kW

                                    1300 Series: Fan and alternator combined – 13kW

§         Air inlet temperature: 20 degrees Celsius

§         Nominal tolerance on Power output: +3% -5%

                                                  

                                                                                                                          
                                                                                                                                                                                   403C-1515
                               1104C-44TA

 

 


For all your Perkins Power Products:

Diesel Parts & Service Pty Ltd

Ph: (07) 32681062                                                                       Fax: (07) 38681330                                            email: info@dieselparts.com.au